WELCOME TO

 

 

HOME

PRODUCTS

CONTACT US

ABOUT US

 

ESD PERSONAL IONIZER

DESCRIPTION

The PR588 Personal Ionizer is compact and lightweight. This is an auto-balance Ionizer and the emitter pin can be clean and replace easily. It has a maximizing neutralization efficiency and overall performance.

 

OPERATION

The PR588 had an on/off switch and variable fan speed. Higher the fan speed and have maximum airflow direct to the items or area to be neutralized.

 

MAINTENANCE

All Ionizer need a maintenance for Optimum performance (Reference IEC 61340-5-2:1 paragraph 5.2.9 )

 

The frequency of monitoring Ionizers really depends on how and where there are used. Since the majority of them use a fan to transport the ions to the working area, the cleanliness of the air directly affects their performance average time and how often the emitters should be cleaned.

 

It is recommend to check Ionizer every 6 months, but this may no be suitable for many programs particularly an out of order may exist for months before it is check again. The Desco or 3M charge plate can be use to check the result.

 

WARRANTY

The personal Ionizer has a one year warranty from the date of purchase.

 

Note:

Warranty will be void on the miss handling and wrong power supply use.

 

SPECIFICATION

Model

PR588

Input Voltage

AC 220V / 50Hz ; 110V / 60Hz

Working Voltage

DC 12V

Power Consumption

12W

Air Volume

20 100CFM

Working Temperature

0 Degree C 50 Degree C

Working Humidity

40% RH 70% RH

Offset Voltage

0+- 3V

Discharge Time

<=1.2s (300mm)

Noise

<=41dB

Size

180mm * 65mm * 195mm

Weight

1.0Kg

 

ELIMINATING STATIC CHRONOMETRY

Testing Contents

Air Speed

Center Test Distance

Offset Voltage

Discharge Time

Testing Result

100CFM

300mm

0 +- 3V

<=1.2s

100CFM

600mm

0 +- 3V

<=2.0s

 

-Small and light

-High precision ion balance

-Eliminate static rapidly

-Discharge needle used longer and easily to change

-Normally with exceptionally function through LED, and also alarming as exceptionally

-Adopting the rectification, the filter and time of pressure, so that the voltage undulates slightly, the performance is reliable

 

 

BACK